PO2-H

Oxygen controlled System

Conductivity Cell

Some measurements are not requiring single instruments working alone, but fully equipped systems that are able to cover all the aspects of the sample conditioning.

Variable partial pressure of oxygen environments are used for testing the most advanced materials in ionic conductors field, but the quality of the measures is directly proportional  to the performance of the gas system.

The PO2-H  system, from Material Mates, offers all these features in a compact  and very attractive design.

With a top temperature of 1100 C°, a gas tight furnace zone and a high performance oxygen pump gauge, the system drives the sample down to a minimum of 10–19 bar of PO2 for the most demanding application.

A full range of accessories is ready to complete the system , covering gas detection for safety issues or even an oxygen sensor mounted near the sample for the ultimate precision.

Contact us to find our more on the features of this system and the range of possible add-ons available from us.

OVEN
Temperature range 0-1100 C°
Inner volume (usable) 60 mm x 80 mm dia with < 1 C° uniformity
Controller Eurotherm 2216e
Thermocouple (oven) Type S
Interface RS-232 serial port
Communication protocol MODBUS
Orientation Vertical
Loading From the bottom
Controlled atmosphere Gas and primary vacuum allowed
Other features Electric lift for the sample holderFlush gas needle valve/ flow displayGas out valve
PUMP- GAUGE
Pumping performance down to 10 e-23 on flow up to 13 lt/hr
Measuring system internal reference zirconia sensor
Measuring range down to 10 e-35
OPTIONS
Safety
Gas Explosivity detector with automatic flush control for ultimate H2 studies
Sample  temperature Second controller with readout, RS-232 interface and Termoplot software (including cables and thermocouple)
Measure
Gas oxygen sensor  mounted in the cell and meter
Physical Thermal gradient (with additional heater)
Software Oxygen partial pressure measuring and ramping software
POWER SUPPLY AND SIZE
Voltage mains 115 / 230 V ranges (+/- 10%)
Power consumption 1500 VA max
Size & weight Approx  450 x 430 x 630 mm (L x W x H) Kg 12 
Measuring Systems and Sample Holders in controlled environment from 10 to 1500 K° Materials Mates is partner of Flexible Concepts® “engineering for a new millennium”
Webmastered by Alessandro Baici - Valid W3C xhtml and css - Last modified: Thursday, 15-Sep-2005 12:33:00 CEST
Materials Mates ® 1 Route de Chaufour, 78270 Cravent (France) – www.mmates.com
Sales and Info + 33 6 08.45.30.25 or + 33 6 99.64.18.34 – Tech + 39 39.39.00.20.69 – Fax + 33 4.76.43.32.65 - email
finepagina